ERREPI GRT10-R-TM
Powerful online UPS for 19-inch rack installation with 10000 VA and 10000 W. The system offers a three-phase input, a single-phase output, and a maintenance-free lead-acid battery for maximum reliability.
Shop
Powerful online UPS for 19-inch rack installation with 10000 VA and 10000 W. The system offers a three-phase input, a single-phase output, and a maintenance-free lead-acid battery for maximum reliability.
This uninterruptible power supply uses state-of-the-art online technology and is specifically designed for professional installation in 19-inch cabinets. With an enormous output of 10000 VA and 10000 W, the system reliably protects sensitive hardware from power failures. The unit features a three-phase input and a single-phase output. The extensive standard equipment includes an automatic bypass, an energy-saving ECO mode, and a long-lasting, completely maintenance-free lead-acid battery. For easy local management, RS232 and USB interfaces are integrated. The matching data cable and comprehensive management and shutdown software are already included in the scope of delivery. If required, the system can be expanded with optional components such as an AS400 interface OP GRT, an external service bypass BY63-f-3/1, or an SNMP adapter SNMP-GRT. The UPS requires 5 rack units with dimensions of 435 millimeters in width and 559 millimeters in depth. An additional 100 millimeters of space at the rear must be allowed for safe cabling of the connections. The total weight of the compact unit is exactly 76.2 kilograms.
Please always observe the basic safety regulations when installing and using the UPS system. Because life-threatening voltage levels are present inside the system, the IP20 enclosure may only be opened by qualified service personnel. Make sure the system is properly grounded and operated in a compatible TN, IT or TT power system. Be sure to compare the rating plate information with your mains supply and the total power consumption of the connected devices in advance. To avoid fire hazards, the device may only be connected to a circuit protected by an easily accessible circuit breaker (rated at 20A, C tripping characteristic). For hardwired systems, an external disconnect switch is required, while for plug-in devices the socket must be in the immediate vicinity and easily accessible. Always follow all connection and operating instructions in the manual in the exact order specified. Choose the installation location of the UPS carefully. The system must never be installed near liquids, in excessively humid environments or in direct sunlight, or near heat sources. Make sure that no foreign objects enter the interior and that the ventilation grilles are never blocked to ensure adequate cooling. If interim storage is necessary, it must take place in a dry location. Permissible storage temperatures are between -25 °C and +55 °C without batteries and between 0 °C and +40 °C with batteries, with temperatures below 25 °C recommended for optimal battery life. Special caution is required when handling the installed batteries, as they contain small amounts of toxic substances and pose a risk of electric shock as well as high short-circuit currents. Maintenance may only be performed or supervised by personnel familiar with the necessary precautions. When replacing batteries, exactly the same battery type and the same number of batteries must be used, as incorrect models create a risk of explosion. Batteries must under no circumstances be disposed of in fire, opened or mechanically destroyed. The electrolyte released in this process is toxic and can cause severe chemical burns to skin and eyes. Always dispose of used batteries properly and in accordance with the applicable legal requirements.
This product and the batteries contained in it are subject to strict European and national environmental regulations and must never be disposed of with normal household waste at the end of their service life. The crossed-out wheeled bin symbol on the device indicates that the UPS system must be collected separately from unsorted municipal waste. Please take the end-of-life device to an official municipal collection point, such as a recycling center, or return it to an electronics retailer or the manufacturer for proper recycling. Remember to reset network-capable management cards to factory settings in advance to delete any stored network configurations. Special attention is required for the lead-acid batteries installed in the UPS, as they contain toxic heavy metals and corrosive acids that can cause serious environmental damage if disposed of improperly. Remove the batteries from the system before disposal whenever possible and take them to separate battery collection. Used industrial batteries can be returned free of charge to the manufacturer, the distributor or special take-back systems. To avoid short circuits and the associated fire or explosion hazards, cover the exposed battery terminals with insulating tape before transport. Packaging materials should also be recycled properly for the sake of the environment: dispose of cardboard and paper with waste paper, while films, Styrofoam and plastic straps belong in the appropriate recyclable materials collection, such as the Yellow Bag or Yellow Bin.
| Product data | |
|---|---|
| Product number | USV-R0100-GT002 |
| Unit | pc |
| Electrical basics | |
| Apparent power | 10000 VA |
| Active power | 10000 W |
| Mechanical & installation | |
| Form factor / mounting standard | 19-inch rack |
| Rack units | 5 HE |
| Abmessungen (B x H x T) | 482.6 x 222.25 x 559 mm |
| Net weight | 76.2 kg |
Accessories and service
The correct SNMP adapter is the SNMP-GRT.