Consulting and project planning

Plan UPS projects with confidence

From the first load survey to the right system: ERREPI supports companies, planners and system integrators with UPS sizing, project planning, tenders and service concepts.

The right UPS solution takes more than a power rating. What counts is the load profile, protection requirements, runtime, installation site, maintainability and how the system will be integrated into operation and service.

Advice for sound UPS decisions

ERREPI helps you translate requirements clearly: from the critical application through power and runtime to accessories, monitoring, bypass and maintenance. That turns an enquiry into a transparent technical concept.

This is particularly useful when existing systems are being extended, new sites are being set up, tenders are being prepared or different groups of loads have different levels of criticality.

Define requirements

The starting point is which loads need protection and what a failure would put at risk. Servers, network, telephony, access control, tills, laboratories, controls and production all differ in their requirements for protection class, runtime and transfer behaviour.

QuestionWhy it matters
Which loads are critical?Determines priority, power and possible load groups.
How much runtime is needed?Determines battery size, footprint, weight and recharge time.
Must maintenance be possible without shutdown?Determines the bypass concept and serviceability.
Are there monitoring or shutdown requirements?Determines interfaces, SNMP cards and software integration.

UPS sizing with reserve and real-world sense

Proper sizing looks beyond watts or VA to power factor, inrush currents, reserve, battery ageing, ambient temperature and expandability. This prevents a system that looks right on paper from turning out undersized in operation.

Different technologies come into question depending on the protection required. Classifications such as VFI, VI and VFD make operating behaviour comparable.

Project planning for site, rack and operation

Beyond the UPS itself, projects involve the environment, mounting, cabling, rack installation, battery modules, service access, cooling, power quality and future maintenance. ERREPI helps you choose the right combination of system, accessories and scope of service.

For server rooms, network cabinets and multiple sites, a coordinated concept helps establish standards while still allowing for site-specific requirements.

Specifications and tenders

During planning and tendering, we can review technical requirements, sanity-check line items and prepare suitable product proposals or alternatives. The goal is a clear, comparable basis for quotations and implementation.

If a specification already exists, ERREPI can review the UPS-related requirements for technical consistency, accessories needed, serviceability and potential risks.

For planners, system integrators and operators

Planners get technical guidance and product-level support. System integrators can quote customer projects in a more structured way. Operators get a clear basis for deciding on replacement, expansion or new purchases.

The solution stays easy to follow: which load is protected, why a particular design was chosen and which service and monitoring options make sense.

Typical process

  1. Describe the requirement, the application and the existing environment.
  2. Collect load data, required runtime and site conditions.
  3. Agree on the technical design and suitable solution options.
  4. Combine products, accessories, service and monitoring in one quotation.
  5. Support tender or project documents where needed.

Useful information to prepare

  • Loads, power in watts or VA and the reserve you want.
  • Required runtime or shutdown target.
  • Installation site, rack situation, ambient temperature and space available.
  • Existing UPS, battery age and past faults.
  • Requirements for SNMP, alerts, shutdown or building services.
  • Maintenance windows, bypass requirements and service expectations.

Quality management to ISO 9001

Project planning and UPS sizing call for careful clarification and structured processes. ERREPI's quality management system is certified to ISO 9001 for the manufacture of innovative power supplies.

Quality management at ERREPI

Further reading

For the basics of choosing a UPS, see UPS knowledge and the UPS glossary. For operation, maintenance and battery replacement, visit the service section. Products and accessories are in the shop; for specific project enquiries, contact us.