ERREPI GRT10-TM
UPS

UPS

ERREPI GRT10-TM

This high-performance online UPS system—a robust tower unit with a 10,000-watt capacity—provides reliable protection for your critical systems. It features a three-phase input, a single-phase output, and a maintenance-free lead-acid battery to ensure maximum security during power outages.

Product description

The uninterruptible power supply in advanced online technology ensures maximum reliability for sensitive electronics. With a rated output of 10000 VA and 10000 W, this stand-alone unit reliably protects against grid fluctuations and power outages. The system handles a three-phase input and delivers a clean single-phase output. The integrated ECO mode ensures energy-efficient operation, while the automatic bypass provides additional redundancy. The integrated, completely maintenance-free lead-acid battery ensures immediate power supply in an emergency. Control and monitoring are conveniently handled via the standard RS232 interface or USB interface, with the required data cable as well as the management software and shutdown software already included in the scope of delivery. The system can be optimally adapted to your specific infrastructure with optional accessories such as the AS400 interface OP GRT, the external service bypass BY63-f-3/1, and the SNMP adapter SNMP-GRT. With dimensions of 5 rack units, a width of 435 millimeters, and a depth of 559 millimeters, the 76.2-kilogram device can be positioned ideally. Please note the mandatory 100 millimeters of space at the rear for all cables and connections during installation.

Notes

Safety information

Please always observe the basic safety regulations when installing and using the UPS system. Because life-threatening voltage levels are present inside the system, the IP20 enclosure may only be opened by qualified service personnel. Make sure the system is properly grounded and operated in a compatible TN, IT or TT power system. Be sure to compare the rating plate information with your mains supply and the total power consumption of the connected devices in advance. To avoid fire hazards, the device may only be connected to a circuit protected by an easily accessible circuit breaker (rated at 20A, C tripping characteristic). For hardwired systems, an external disconnect switch is required, while for plug-in devices the socket must be in the immediate vicinity and easily accessible. Always follow all connection and operating instructions in the manual in the exact order specified. Choose the installation location of the UPS carefully. The system must never be installed near liquids, in excessively humid environments or in direct sunlight, or near heat sources. Make sure that no foreign objects enter the interior and that the ventilation grilles are never blocked to ensure adequate cooling. If interim storage is necessary, it must take place in a dry location. Permissible storage temperatures are between -25 °C and +55 °C without batteries and between 0 °C and +40 °C with batteries, with temperatures below 25 °C recommended for optimal battery life. Special caution is required when handling the installed batteries, as they contain small amounts of toxic substances and pose a risk of electric shock as well as high short-circuit currents. Maintenance may only be performed or supervised by personnel familiar with the necessary precautions. When replacing batteries, exactly the same battery type and the same number of batteries must be used, as incorrect models create a risk of explosion. Batteries must under no circumstances be disposed of in fire, opened or mechanically destroyed. The electrolyte released in this process is toxic and can cause severe chemical burns to skin and eyes. Always dispose of used batteries properly and in accordance with the applicable legal requirements.

Disposal information

This product and the batteries contained in it are subject to strict European and national environmental regulations and must never be disposed of with normal household waste at the end of their service life. The crossed-out wheeled bin symbol on the device indicates that the UPS system must be collected separately from unsorted municipal waste. Please take the end-of-life device to an official municipal collection point, such as a recycling center, or return it to an electronics retailer or the manufacturer for proper recycling. Remember to reset network-capable management cards to factory settings in advance to delete any stored network configurations. Special attention is required for the lead-acid batteries installed in the UPS, as they contain toxic heavy metals and corrosive acids that can cause serious environmental damage if disposed of improperly. Remove the batteries from the system before disposal whenever possible and take them to separate battery collection. Used industrial batteries can be returned free of charge to the manufacturer, the distributor or special take-back systems. To avoid short circuits and the associated fire or explosion hazards, cover the exposed battery terminals with insulating tape before transport. Packaging materials should also be recycled properly for the sake of the environment: dispose of cardboard and paper with waste paper, while films, Styrofoam and plastic straps belong in the appropriate recyclable materials collection, such as the Yellow Bag or Yellow Bin.

Technical data

Product data
Product numberUSV-T0100-GT002
Unitpc
Electrical basics
Apparent power10000 VA
Active power10000 W
TopologyOnline VFI
Phases3-phasig / 1-phasig
Battery & runtime
Battery expansion optionalYes
Mechanical & installation
Form factor / mounting standardTower / standalone unit
Abmessungen (B x H x T)225 x 589 x 416 mm
Net weight68 kg
Interfaces & monitoring
DisplayLCD
SNMP optionalYes
Service bypass optionalYes

Accessories and service

Frequently asked questions

What is the correct SNMP adapter?

The correct SNMP adapter is the SNMP-GRT.