ERREPI NetPower 2000
USB
UPS

UPS

ERREPI NetPower 2000

Maximum power: 2000 VA / 1600 W, line-interactive UPS in a tower enclosure. Delivers pure sine wave power for critical IT infrastructure, including management software and USB interface.

Product description

The ERREPI NP 2000 is the powerhouse of the series for demanding hardware. As a state-of-the-art line-interactive (VI) UPS, it provides 2000 VA / 1600 W capacity. By outputting a pure sine wave, it also protects highly sensitive systems reliably from data loss and hardware damage. The tower unit operates with durable maintenance-free lead batteries and a USB interface. The included shutdown software and data cables allow immediate commissioning and configuration.

Notes

Safety information

Please always observe the basic safety regulations when installing and using the UPS system. Because life-threatening voltage levels are present inside the system, the IP20-rated housing may only be opened by qualified service personnel. Make sure the system is properly grounded and operated in a compatible TN, IT or TT power system. Be sure to compare the nameplate data with your power grid and the total power consumption of the connected devices in advance. To avoid fire risk, the unit may only be connected to a circuit protected by an easily accessible circuit breaker (rated at 20 A, C trip curve). For hardwired systems, an external disconnect switch is required, while for plug-in devices the socket must be in immediate proximity and easily accessible. Always follow all connection and operating instructions in the manual in the exact order specified. Choose the installation location of the UPS carefully. The system must never be installed near liquids, in excessively humid environments, in direct sunlight or near heat sources. Make sure that no foreign objects enter the interior and that the ventilation grilles are never blocked so adequate cooling is ensured. If interim storage is necessary, it must be carried out in a dry place. Permissible storage temperatures are between -25 C and +55 C without batteries and between 0 C and +40 C with batteries, with temperatures below 25 C recommended for optimal battery life. Special care is required when handling the installed batteries, because they contain small amounts of toxic substances and pose a risk of electric shock and high short-circuit currents. Their maintenance may only be carried out or supervised by personnel familiar with the necessary precautions. When replacing them, exactly the same battery type and the same number of batteries must be used, because incorrect models present an explosion hazard. Batteries must under no circumstances be disposed of in fire, opened or mechanically destroyed. The electrolyte that escapes is toxic and can cause severe chemical burns to the skin and eyes. Always dispose of used batteries properly and in accordance with applicable legal requirements.

Disposal information

This product and the batteries it contains are subject to strict European and national environmental regulations and must not be disposed of with normal household waste at the end of their service life. The crossed-out wheeled bin symbol on the device indicates that the UPS system must be collected separately from unsorted municipal waste. Please take the retired device to an official municipal collection point, such as a recycling center, or return it to an electronics retailer or the manufacturer for proper recycling. Remember to reset network-capable management cards to factory settings beforehand so that any stored network configurations are deleted. The lead-acid batteries installed in the UPS require special attention because they contain toxic heavy metals and corrosive acids that can cause severe environmental damage if disposed of improperly. If possible, remove the batteries from the system before disposal and send them to a separate battery collection facility. Used industrial batteries can be handed in free of charge to the manufacturer, the distributor, or to special take-back systems. To avoid short circuits and the associated fire or explosion hazards, tape over the exposed battery terminals with insulating tape before transport. Packaging materials should also be recycled properly for the sake of the environment: dispose of cardboard and paper with waste paper, while foil, Styrofoam, and plastic straps belong in the appropriate recyclables collection, such as the Yellow Bag or Yellow Bin.

Technical data

Product data
Product numberUSV-T0020-GT002
Unitpc
Electrical basics
Apparent power2000 VA
Active power1600 W
TopologyLine-Interactive
Battery-mode output waveformPure sine wave
Input connection230
Output connections230
Mechanical & installation
Form factor / mounting standardTower / standalone unit
Abmessungen (B x H x T)146 x 205 x 397 mm
Net weight13.7 kg
Interfaces & monitoring
USB interfaceYes

Accessories and service

Frequently asked questions

How does a line-interactive uninterruptible power supply work?

A line-interactive UPS continuously monitors the incoming mains voltage and automatically compensates voltage fluctuations. In the event of a power outage or a significant mains disturbance, the system switches to battery operation within a very short time and continues to supply the connected devices with power.

What are the advantages of the integrated USB interface?

Via the USB interface, the UPS can be connected to a computer or server. This makes it possible to monitor operating data, issue warning messages, and, depending on the software used, perform automatic measures such as a safe shutdown of the system during longer power outages.