ERREPI OnPower GRT1-R
UPS

UPS

ERREPI OnPower GRT1-R

The compact 1000 VA online UPS protects your network hardware with high efficiency in only 2 rack units in the 19-inch rack.

Product description

Protect the heart of your IT infrastructure with this professional rack UPS. It uses safe online technology and delivers clean power immediately and without interruption when the mains is disturbed. Its compact design fits seamlessly into your 19-inch server cabinet and saves valuable space. It compensates voltage fluctuations effortlessly and, thanks to the wide input voltage range, protects the maintenance-free lead battery. In normal operation, the smart ECO mode reduces your energy costs. With the included management software, you can keep a constant eye on the system status and initiate a safe, automated shutdown of servers during longer power outages.

Notes

Safety information

Please always observe the basic safety regulations when installing and using the UPS system. Because life-threatening voltage levels are present inside the system, the IP20 enclosure may only be opened by qualified service personnel. Make sure the system is properly grounded and operated in a compatible TN, IT, or TT power system. Be sure to compare the nameplate data with your mains supply and the total power consumption of the devices to be connected. To avoid fire risk, the device may only be connected to a circuit protected by an easily accessible circuit breaker (rated 20 A, tripping curve C). For hardwired systems, an external disconnect switch is required, while for plug-in devices the socket must be nearby and easily accessible. Always follow all connection and operating instructions in the manual in the exact order given. Choose the installation location of the UPS carefully. The system must never be installed near liquids, in excessively humid environments, or in direct sunlight or near heat sources. Make sure no foreign objects can enter the interior and that the ventilation grilles are never blocked so adequate cooling is maintained. If temporary storage is necessary, it must be in a dry location. Permissible storage temperatures are between -25 °C and +55 °C without batteries and between 0 °C and +40 °C with batteries, with temperatures below 25 °C recommended for optimum battery service life. Special caution is required when handling the installed batteries, as they contain small amounts of toxic substances and pose a risk of electric shock and high short-circuit currents. Maintenance may only be performed or supervised by personnel familiar with the required precautions. When replacing them, exactly the same battery type and the same number of batteries must be used, as incorrect models pose an explosion hazard. Batteries must under no circumstances be disposed of in fire, opened, or mechanically destroyed. The electrolyte released in the process is toxic and can cause severe burns to the skin and eyes. Always dispose of used batteries properly and in accordance with applicable legal requirements.

Disposal information

This product and the batteries contained in it are subject to strict European and national environmental regulations and must never be disposed of with normal household waste at the end of their service life. The crossed-out wheeled bin symbol on the device indicates that the UPS system must be collected separately from unsorted municipal waste. Please take the retired device to an official municipal collection point, such as a recycling center, or return it to an electronics retailer or the manufacturer for proper recycling. Remember to reset network-capable management cards to factory settings beforehand to delete any stored network configurations. The lead-acid batteries installed in the UPS require special attention, as they contain toxic heavy metals and corrosive acids that can cause serious environmental damage if disposed of improperly. If possible, remove the batteries from the unit before disposal and take them to a separate battery collection point. Used industrial batteries can be returned free of charge to the manufacturer, the distributor, or special take-back systems. To avoid short circuits and the associated fire or explosion hazards, tape over the exposed battery terminals with insulating tape before transport. Packaging materials should also be recycled properly for the sake of the environment: dispose of cardboard and paper with waste paper, while films, Styrofoam, and plastic straps belong in the appropriate recyclable materials collection, such as the Yellow Bag or Yellow Bin.

Technical data

Product data
Product numberUSV-R0010-GT001
Unitpc
Electrical basics
Apparent power1000 VA
Active power1000 W
TopologyOnline VFI
Phases1-phasig / 1-phasig
Battery & runtime
Battery expansion optionalYes
Mechanical & installation
Form factor / mounting standard19-inch rack
Rack units2 HE
Abmessungen (B x H x T)438 x 85.5 x 445 mm
Net weight14.3 kg
Interfaces & monitoring
DisplayLCD
SNMP optionalYes
Service bypass optionalYes

Accessories and service

Frequently asked questions

Can I connect an external service bypass?

Yes, the correct product is the BY10-R.

Which is the correct SNMP adapter for the ERREPI GRT1-R UPS?

The correct SNMP adapter is the SNMP-GRT.

If I load the UPS with only half the load, what backup runtime results?

At a load of 500 VA, the backup runtime is 10 minutes.