ERREPI RPT 1000
USB
UPS

UPS

ERREPI RPT 1000

Secure your electronics reliably against power outages with this compact line-interactive UPS (1000 VA / 600 W). The 5.4 kg unit impresses with automatic voltage regulation (AVR), an energy-saving Green mode, and a clear LED display. It is delivered ready to use immediately, including a maintenance-free lead battery, USB interface, and practical management software.

Product description

Power outages or voltage fluctuations can damage sensitive electronic devices and lead to massive data loss. With our line-interactive uninterruptible power supply (UPS), you can protect your hardware effectively and reliably. In battery mode, the unit generates a simulated sine wave that is ideal for most PC power supplies and standard electronics. Thanks to the integrated automatic voltage regulation (AVR), under- and overvoltage from the power grid are compensated directly without placing a load on the battery. This protects the battery and significantly extends its service life. An optional Green mode also ensures especially energy-efficient operation in everyday use. The integrated LED display keeps you informed of the current operating status at all times, while an automatic system test with alarm notification guarantees that the system functions flawlessly in an emergency. The UPS is equipped with a maintenance-free lead battery and is ready to use immediately. For easy monitoring and maintenance, a USB cable and powerful management software are included in the scope of delivery. This allows you to conveniently monitor the system via your computer and configure a safe, automatic shutdown of your computer systems during a longer power outage.

Notes

Safety information

Please always observe the basic safety regulations when installing and using the UPS system. Since life-threatening voltage levels are present inside the system, the IP20 enclosure may only be opened by qualified service personnel. Make sure the system is properly grounded and operated in a compatible TN, IT, or TT power system. Beforehand, be sure to compare the nameplate data with your power grid and the total consumption of the devices to be connected. To avoid fire hazard, the unit may only be connected to a circuit protected by an easily accessible circuit breaker (rated 20A, trip curve C). For hardwired systems, an external disconnect switch is required, while for plug-in units the socket must be in close proximity and easily accessible. Always follow all connection and operating instructions in the manual in the exact order given. Choose the installation location for the UPS carefully. The system must never be installed near liquids, in excessively humid environments, or in direct sunlight or near heat sources. Make sure no foreign objects can enter the interior and the ventilation grilles are never blocked so that adequate cooling is ensured. If interim storage is necessary, it must be carried out in a dry place. Permissible storage temperatures are between -25 °C and +55 °C without batteries and between 0 °C and +40 °C with batteries, with temperatures below 25 °C recommended for optimal battery life. Special caution is required when handling the installed batteries, as they contain small amounts of toxic substances and pose a risk of electric shock as well as high short-circuit currents. Maintenance may only be carried out or supervised by personnel familiar with the necessary precautions. When replacing batteries, exactly the same battery type and the same number of batteries must be used, as incorrect models create an explosion hazard. Batteries must never be disposed of in fire, opened, or mechanically destroyed. The electrolyte released in such a case is toxic and can cause severe burns to the skin and eyes. Always dispose of used batteries properly and in accordance with the applicable legal regulations.

Disposal information

This product and the batteries contained in it are subject to strict European and national environmental regulations and must never be disposed of with normal household waste at the end of their service life. The symbol of the crossed-out wheeled bin on the device indicates that the UPS system must be collected separately from unsorted municipal waste. Please take the retired unit to an official municipal collection point, such as a recycling center, or return it to an electronics retailer or the manufacturer for proper recycling. Remember to reset network-capable management cards to factory settings in advance to delete any stored network configurations. Special attention is required for the lead batteries installed in the UPS, as they contain toxic heavy metals and corrosive acids that can cause serious environmental damage if disposed of improperly. Remove the batteries from the system before disposal if possible and take them to a separate battery collection point. Used industrial batteries can be returned free of charge to the manufacturer, distributor, or special take-back systems. To avoid short circuits and the associated fire or explosion hazards, tape the exposed battery terminals with insulating tape before transport. Packaging materials should also be recycled properly for the sake of the environment: dispose of cardboard and paper with waste paper, while films, Styrofoam, and plastic straps belong in the appropriate recycling collection, such as the yellow bag or yellow bin.

Technical data

Product data
Product numberUSV-T0010-PC001
Unitpc
Electrical basics
Apparent power1000 VA
Active power600 W
TopologyOffline / Standby
Battery-mode output waveformStepped approximation
Transfer time4 ms
Mechanical & installation
Abmessungen (B x H x T)100 x 140 x 278 mm
Net weight5.4 kg
Interfaces & monitoring
USB interfaceYes
Shutdown softwareIncluded

Accessories and service

Frequently asked questions

In which power classes is the ERREPI RPT available?

The ERREPI RPT series is available in the 600 VA, 800 VA, 1000 VA, 1025 VA, 1500 VA and 2000 VA power classes.