ERREPI RPT 1025
USB
UPS

UPS

ERREPI RPT 1025

Protect your hardware and data from power outages with this powerful line-interactive UPS (1025 VA / 615 W). Thanks to Automatic Voltage Regulation (AVR), LCD display, USB interface, and energy-saving Green Mode, it offers optimal protection and easy everyday handling. The matching management software for monitoring on a PC is already included in the scope of delivery.

Product description

Power outages and voltage fluctuations can not only destroy unsaved data, but also permanently damage expensive hardware. With this powerful uninterruptible power supply in line-interactive technology (VI), you are on the safe side. With its output of 1025 VA (615 watts), it bridges power outages reliably by using a maintenance-free lead-acid battery, which delivers a simulated sine wave in battery mode. The integrated Automatic Voltage Regulation (AVR) balances minor undervoltage and overvoltage without immediately loading the battery, effectively protecting the battery and extending its service life. The easy-to-read LC display keeps the current status of the UPS in view at all times, while an automatic system test with alarm warning alerts you early to irregularities. For environmentally conscious users, the compact device weighing 8.4 kilograms (dimensions: 164 x 146 x 360 millimeters) offers a selectable Green Mode that noticeably optimizes energy consumption. Thanks to the plug-and-play USB interface and the included USB cable, the UPS can be connected to your PC or server with ease. The included management software finally enables convenient automatic shutdown of systems as well as detailed monitoring of the power supply.

Notes

Safety information

Please always observe the basic safety regulations when installing and using the UPS system. Since life-threatening voltage levels are present inside the system, the IP20 enclosure may only be opened by qualified service personnel. Make sure the system is properly grounded and operated in a compatible TN, IT, or TT power system. Beforehand, be sure to compare the nameplate data with your power grid and the total consumption of the devices to be connected. To avoid fire hazard, the unit may only be connected to a circuit protected by an easily accessible circuit breaker (rated 20A, trip curve C). For hardwired systems, an external disconnect switch is required, while for plug-in units the socket must be in close proximity and easily accessible. Always follow all connection and operating instructions in the manual in the exact order given. Choose the installation location for the UPS carefully. The system must never be installed near liquids, in excessively humid environments, or in direct sunlight or near heat sources. Make sure no foreign objects can enter the interior and the ventilation grilles are never blocked so that adequate cooling is ensured. If interim storage is necessary, it must be carried out in a dry place. Permissible storage temperatures are between -25 °C and +55 °C without batteries and between 0 °C and +40 °C with batteries, with temperatures below 25 °C recommended for optimal battery life. Special caution is required when handling the installed batteries, as they contain small amounts of toxic substances and pose a risk of electric shock as well as high short-circuit currents. Maintenance may only be carried out or supervised by personnel familiar with the necessary precautions. When replacing batteries, exactly the same battery type and the same number of batteries must be used, as incorrect models create an explosion hazard. Batteries must never be disposed of in fire, opened, or mechanically destroyed. The electrolyte released in such a case is toxic and can cause severe burns to the skin and eyes. Always dispose of used batteries properly and in accordance with the applicable legal regulations.

Disposal information

This product and the batteries it contains are subject to strict European and national environmental regulations and must under no circumstances be disposed of in normal household waste at the end of their service life. The crossed-out wheeled bin symbol on the device indicates that the UPS system must be collected separately from unsorted municipal waste. Please take the retired device to an official municipal collection point, such as a recycling center, or return it to an electronics dealer or the manufacturer for proper recycling. Remember to reset network-capable management cards to factory settings in advance so that any stored network configurations are deleted. Special attention is required for the lead-acid batteries installed in the UPS, because they contain toxic heavy metals and corrosive acids that can cause severe environmental damage if disposed of improperly. If possible, remove the batteries from the system before disposal and take them to separate battery collection. Used industrial batteries can be returned free of charge to the manufacturer, distributor or special take-back systems. To avoid short circuits and the associated fire or explosion risks, tape over the exposed battery terminals with insulating tape before transport. Packaging materials should also be recycled properly for the sake of the environment: dispose of cardboard and paper with waste paper, while films, Styrofoam and plastic straps belong in the appropriate recycling collection, such as the yellow bag or yellow bin.

Technical data

Product data
Product numberUSV-T0010-PC002
Unitpc
Electrical basics
Apparent power1025 VA
Active power615 W
TopologyOffline / Standby
Battery-mode output waveformStepped approximation
Transfer time4 ms
Mechanical & installation
Abmessungen (B x H x T)146 x 164 x 360 mm
Net weight8.4 kg
Interfaces & monitoring
USB interfaceYes
Shutdown softwareIncluded

Accessories and service

Frequently asked questions

In which power classes is the ERREPI RPT available?

The ERREPI RPT series is available in the 600 VA, 800 VA, 1000 VA, 1025 VA, 1500 VA and 2000 VA power classes.

How many connection options for loads does the UPS have?

The UPS output on the rear has 6 IEC sockets 230V/50Hz.