ERREPI RPT 1500
USB
UPS

UPS

ERREPI RPT 1500

Reliable line-interactive UPS (1500 VA / 900 W) with Automatic Voltage Regulation (AVR) and LCD display to protect your hardware from power outages. Includes a maintenance-free battery, USB connection, and intelligent management software.

Product description

Protect your valuable hardware and important data reliably from power outages and voltage fluctuations with this powerful uninterruptible power supply (UPS) in line-interactive technology (VI). With an output of 1500 VA or 900 W and the integrated Automatic Voltage Regulation (AVR), the device immediately compensates for irregularities in the power grid without unnecessarily loading the battery. In the event of a complete power outage, the integrated, maintenance-free lead-acid battery provides energy immediately in the form of a simulated sine wave, giving you enough time to save running processes and shut systems down in a controlled manner. A clear LC display keeps you informed of the current operating status at a glance at all times. Thanks to the selectable Green Mode, the UPS can be operated particularly energy efficiently. The device's permanent readiness is ensured by an automatic system test that warns you immediately by alarm if needed. The practical USB interface and the included USB cable ensure smooth communication with your PC. The package is rounded off by the management software included in the scope of delivery, which gives you convenient monitoring and control of the power supply directly from your computer.

Notes

Safety information

Please always observe the basic safety regulations when installing and using the UPS system. Since life-threatening voltage levels are present inside the system, the IP20 enclosure may only be opened by qualified service personnel. Make sure the system is properly grounded and operated in a compatible TN, IT, or TT power system. Beforehand, be sure to compare the nameplate data with your power grid and the total consumption of the devices to be connected. To avoid fire hazard, the unit may only be connected to a circuit protected by an easily accessible circuit breaker (rated 20A, trip curve C). For hardwired systems, an external disconnect switch is required, while for plug-in units the socket must be in close proximity and easily accessible. Always follow all connection and operating instructions in the manual in the exact order given. Choose the installation location for the UPS carefully. The system must never be installed near liquids, in excessively humid environments, or in direct sunlight or near heat sources. Make sure no foreign objects can enter the interior and the ventilation grilles are never blocked so that adequate cooling is ensured. If interim storage is necessary, it must be carried out in a dry place. Permissible storage temperatures are between -25 °C and +55 °C without batteries and between 0 °C and +40 °C with batteries, with temperatures below 25 °C recommended for optimal battery life. Special caution is required when handling the installed batteries, as they contain small amounts of toxic substances and pose a risk of electric shock as well as high short-circuit currents. Maintenance may only be carried out or supervised by personnel familiar with the necessary precautions. When replacing batteries, exactly the same battery type and the same number of batteries must be used, as incorrect models create an explosion hazard. Batteries must never be disposed of in fire, opened, or mechanically destroyed. The electrolyte released in such a case is toxic and can cause severe burns to the skin and eyes. Always dispose of used batteries properly and in accordance with the applicable legal regulations.

Disposal information

This product and the batteries contained in it are subject to strict European and national environmental regulations and must never be disposed of with normal household waste at the end of their service life. The symbol of the crossed-out wheeled bin on the device indicates that the UPS system must be collected separately from unsorted municipal waste. Please take the retired unit to an official municipal collection point, such as a recycling center, or return it to an electronics retailer or the manufacturer for proper recycling. Remember to reset network-capable management cards to factory settings in advance to delete any stored network configurations. Special attention is required for the lead batteries installed in the UPS, as they contain toxic heavy metals and corrosive acids that can cause serious environmental damage if disposed of improperly. Remove the batteries from the system before disposal if possible and take them to a separate battery collection point. Used industrial batteries can be returned free of charge to the manufacturer, distributor, or special take-back systems. To avoid short circuits and the associated fire or explosion hazards, tape the exposed battery terminals with insulating tape before transport. Packaging materials should also be recycled properly for the sake of the environment: dispose of cardboard and paper with waste paper, while films, Styrofoam, and plastic straps belong in the appropriate recycling collection, such as the yellow bag or yellow bin.

Technical data

Product data
Product numberUSV-T0015-PC001
Unitpc
Electrical basics
Apparent power1500 VA
Active power900 W
TopologyOffline / Standby
Battery-mode output waveformStepped approximation
Transfer time4 ms
Mechanical & installation
Abmessungen (B x H x T)146 x 164 x 360 mm
Net weight10 kg
Interfaces & monitoring
USB interfaceYes
Shutdown softwareIncluded

Accessories and service

Frequently asked questions

In which power classes is the ERREPI RPT available?

The ERREPI RPT series is available in the 600VA, 800VA, 1000VA, 1025VA, 1500VA and 2000VA power classes.

How many connection options does the UPS have for connected loads?

The UPS output has 6 IEC sockets 230V/50Hz on the rear.