This compact line-interactive UPS system (600 VA / 360 W) with automatic voltage regulation (AVR) reliably protects your devices from power outages and voltage fluctuations. It offers a clear LED display, an energy-saving Green mode, and delivers a stepped sine wave in battery operation. A maintenance-free lead battery, a USB cable, and practical management software are already included.

Product description

Protect your valuable hardware and important data with this powerful line-interactive UPS. Thanks to the integrated automatic voltage regulation, the system compensates under- and overvoltage in the power grid in real time without drawing on the battery directly, which significantly extends the life of the maintenance-free lead battery installed. The integrated LED display reliably informs you at all times about the current operating status of the system. An automatic system test with integrated alarm notification also warns you early of any faults or an impending battery replacement. For environmentally friendly and cost-saving operation, an energy-saving Green mode can be activated if needed. In the event of a power outage, the UPS delivers a stepped sine wave in battery mode, ideal for bridging standard power supplies. The integrated USB interface connects the system easily to your computer. The included management software gives you convenient monitoring of the system and ensures that, during a longer power outage, open files are saved and your PC is shut down in a controlled manner before the battery is exhausted. The included USB cable rounds off this ready-to-use complete package perfectly.

Notes

Safety information

This product and the batteries it contains are subject to strict European and national environmental regulations and must under no circumstances be disposed of in normal household waste at the end of their service life. The crossed-out wheeled bin symbol on the device indicates that the UPS system must be collected separately from unsorted municipal waste. Please take the retired device to an official municipal collection point, such as a recycling center, or return it to an electronics dealer or the manufacturer for proper recycling. Remember to reset network-capable management cards to factory settings in advance so that any stored network configurations are deleted. Special attention is required for the lead-acid batteries installed in the UPS, because they contain toxic heavy metals and corrosive acids that can cause severe environmental damage if disposed of improperly. If possible, remove the batteries from the system before disposal and take them to separate battery collection. Used industrial batteries can be returned free of charge to the manufacturer, distributor or special take-back systems. To avoid short circuits and the associated fire or explosion risks, tape over the exposed battery terminals with insulating tape before transport. Packaging materials should also be recycled properly for the sake of the environment: dispose of cardboard and paper with waste paper, while films, Styrofoam and plastic straps belong in the appropriate recycling collection, such as the yellow bag or yellow bin.

Disposal information

This product and the batteries it contains are subject to strict European and national environmental regulations and must under no circumstances be disposed of in normal household waste at the end of their service life. The crossed-out wheeled bin symbol on the device indicates that the UPS system must be collected separately from unsorted municipal waste. Please take the retired device to an official municipal collection point, such as a recycling center, or return it to an electronics dealer or the manufacturer for proper recycling. Remember to reset network-capable management cards to factory settings in advance so that any stored network configurations are deleted. Special attention is required for the lead-acid batteries installed in the UPS, because they contain toxic heavy metals and corrosive acids that can cause severe environmental damage if disposed of improperly. If possible, remove the batteries from the system before disposal and take them to separate battery collection. Used industrial batteries can be returned free of charge to the manufacturer, distributor or special take-back systems. To avoid short circuits and the associated fire or explosion risks, tape over the exposed battery terminals with insulating tape before transport. Packaging materials should also be recycled properly for the sake of the environment: dispose of cardboard and paper with waste paper, while films, Styrofoam and plastic straps belong in the appropriate recycling collection, such as the yellow bag or yellow bin.

Technical data

Product data
Product numberUSV-T0006-PC001
Unitpc
Electrical basics
Apparent power600 VA
Active power360 W
TopologyOffline / Standby
Battery-mode output waveformStepped approximation
Transfer time4 ms
Mechanical & installation
Abmessungen (B x H x T)100 x 140 x 278 mm
Net weight4.3 kg
Interfaces & monitoring
USB interfaceYes
Shutdown softwareIncluded

Accessories and service

Frequently asked questions

In which power classes is the ERREPI RPT available?

The ERREPI RPT series is available in the 600VA, 800VA, 1000VA, 1025VA, 1500VA and 2000VA power classes.