Shop
External service bypass BY10-R
The external 19-inch service bypass allows the load to be disconnected without interruption for maintenance work on your OnPower GRT1-R series UPS system.
Shop
The external 19-inch service bypass allows the load to be disconnected without interruption for maintenance work on your OnPower GRT1-R series UPS system.
This high-quality maintenance bypass system is specially designed as a compact 19-inch slide-in unit with a height of two rack units and is perfectly suited for integration into standardized network cabinets. The device allows the connected loads to be switched directly to the mains supply during operation safely and without interruption, so that the UPS system of the OnPower GRT1-R series can be fully de-energized for service work or replacement. Connection to the UPS is made reliably via an IEC-60320 C14 appliance plug and a matching C13 appliance coupler, while two separate C13 connections are available for the loads. With a maximum load capacity of ten amperes and an integrated RS232 signal output for status monitoring, this bypass unit offers an optimal combination of safety and functionality at a low installation depth of 170 mm and a weight of only one kilogram.
The installation and commissioning of this service bypass may only be carried out by qualified specialist personnel in compliance with all applicable electrical safety regulations. Before any work on the unit or the connected components, ensure that the maximum permissible current of ten amperes is never exceeded in order to avoid overloads and potential fire hazards. Protect the unit from moisture, dampness and extreme temperatures, because moisture can lead to short circuits and life-threatening electric shocks. Also make sure that all cable connections are tight and undamaged before actuating the bypass switch.
This electronic device must not be disposed of with normal household waste at the end of its service life. As the owner, you are legally obliged to send old devices to separate collection and hand them in at an official municipal collection point or at a qualified electronics retailer. Proper disposal makes a valuable contribution to environmental protection and enables the proper recycling of the raw materials used as well as the safe treatment of potentially harmful substances.
| Product data | |
|---|---|
| Product number | EXB-BY010-ER002 |
| Unit | pc |
| Electrical basics | |
| Phases | 1-phasig / 1-phasig |
| Mechanical & installation | |
| Form factor / mounting standard | 19-inch rack |
| Rated current | 10 A |
| Configuration | Manual |
Accessories and service
An external service bypass allows maintenance or replacement of a UPS system without interrupting the power supply to the connected loads. During service work, the load is safely switched to the public power grid so that critical systems continue to receive power.
The external service bypass is designed for specific UPS models and power ranges. Before installation, check whether the technical specifications of the service bypass match the UPS system in use. You can find compatibility information in the respective product documentation or obtain it from our technical support.