UPS
ERREPI OnPower GRT3-R
Powerful power protection in a compact format: 3000 VA online UPS for highly efficient protection of your network technology in just 2U
UPS
Powerful power protection in a compact format: 3000 VA online UPS for highly efficient protection of your network technology in just 2U
Uninterruptible high-end power protection in rack format. This professional rack UPS provides seamless protection for your central IT hardware. The advanced online topology eliminates voltage fluctuations and filters mains disturbances without delay during power transfer. Its compact design keeps valuable space in the 19-inch rack free for other components. Another advantage: the wide voltage window minimizes battery use and extends the service life of the maintenance-free lead-acid batteries, while the switchable ECO mode optimizes power consumption. With the included monitoring software, you keep the system under control at all times and automate the server shutdown process during longer autonomy times.
Please always observe the basic safety regulations when installing and using the UPS system. Because life-threatening voltage levels are present inside the system, the IP20 enclosure may only be opened by qualified service personnel. Make sure the system is properly grounded and operated in a compatible TN, IT, or TT power system. Be sure to compare the nameplate data with your mains supply and the total power consumption of the devices to be connected. To avoid fire risk, the device may only be connected to a circuit protected by an easily accessible circuit breaker (rated 20 A, tripping curve C). For hardwired systems, an external disconnect switch is required, while for plug-in devices the socket must be nearby and easily accessible. Always follow all connection and operating instructions in the manual in the exact order given. Choose the installation location of the UPS carefully. The system must never be installed near liquids, in excessively humid environments, or in direct sunlight or near heat sources. Make sure no foreign objects can enter the interior and that the ventilation grilles are never blocked so adequate cooling is maintained. If temporary storage is necessary, it must be in a dry location. Permissible storage temperatures are between -25 °C and +55 °C without batteries and between 0 °C and +40 °C with batteries, with temperatures below 25 °C recommended for optimum battery service life. Special caution is required when handling the installed batteries, as they contain small amounts of toxic substances and pose a risk of electric shock and high short-circuit currents. Maintenance may only be performed or supervised by personnel familiar with the required precautions. When replacing them, exactly the same battery type and the same number of batteries must be used, as incorrect models pose an explosion hazard. Batteries must under no circumstances be disposed of in fire, opened, or mechanically destroyed. The electrolyte released in the process is toxic and can cause severe burns to the skin and eyes. Always dispose of used batteries properly and in accordance with applicable legal requirements.
This product and the batteries it contains are subject to strict European and national environmental regulations and must not be disposed of with normal household waste at the end of their service life. The crossed-out wheeled bin symbol on the device indicates that the UPS system must be collected separately from unsorted municipal waste. Please take the retired device to an official municipal collection point, such as a recycling center, or return it to an electronics retailer or the manufacturer for proper recycling. Remember to reset network-capable management cards to factory settings beforehand so that any stored network configurations are deleted. The lead-acid batteries installed in the UPS require special attention because they contain toxic heavy metals and corrosive acids that can cause severe environmental damage if disposed of improperly. If possible, remove the batteries from the system before disposal and send them to a separate battery collection facility. Used industrial batteries can be handed in free of charge to the manufacturer, the distributor, or to special take-back systems. To avoid short circuits and the associated fire or explosion hazards, tape over the exposed battery terminals with insulating tape before transport. Packaging materials should also be recycled properly for the sake of the environment: dispose of cardboard and paper with waste paper, while foil, Styrofoam, and plastic straps belong in the appropriate recyclables collection, such as the Yellow Bag or Yellow Bin.
| Product data | |
|---|---|
| Product number | USV-R0030-GT001 |
| Unit | pc |
| Electrical basics | |
| Apparent power | 3000 VA |
| Active power | 3000 W |
| Topology | Online VFI |
| Phases | 1-phasig / 1-phasig |
| Battery & runtime | |
| Battery expansion optional | Yes |
| Mechanical & installation | |
| Form factor / mounting standard | 19-inch rack |
| Rack units | 2 HE |
| Abmessungen (B x H x T) | 438 x 85.5 x 600 mm |
| Net weight | 26.2 kg |
| Interfaces & monitoring | |
| Display | LCD |
| SNMP optional | Yes |
| Service bypass optional | Yes |
Accessories and service
Yes, the correct product is BY16-R.
The correct SNMP adapter is SNMP-GRT.
No, the angle rails can be purchased from us as an option.